24/7 Emergency Electrical Service CallWhatsApp

MCB Installation

Correctly rated miniature circuit breakers fitted to protect circuits from overload and short circuit.

An MCB (miniature circuit breaker) is the switch in your distribution board that cuts power to a circuit when it overloads or short circuits. It protects the cable in the wall from overheating, and protects you from the damage a fault can cause. Each circuit needs a breaker rated for the cable it protects and the load it carries.

We fit or replace MCBs so that lighting, sockets and heavy appliances each sit on a suitable rating, and we check that the breaker matches the cable behind it. A breaker rated too high will not trip before the wiring overheats, and one rated too low will trip all the time.

New breakers are connected, labelled and tested before we leave.

Problems we solve

  • Breakers that trip repeatedly
  • An old board with missing or mismatched breakers
  • Heavy appliances added to a circuit not meant for them
  • A breaker that feels hot or will not stay on
  • No clear labels showing what each breaker controls
  • No protection on a newly added circuit

Our process

  1. 1

    Check the circuit

    We note the cable size and the load before choosing a rating.

  2. 2

    Select the breaker

    The MCB rating is matched to the cable and the appliances on that circuit.

  3. 3

    Install and connect

    The breaker is fitted in the board with tight, correct connections.

  4. 4

    Label and test

    Each breaker is labelled and tested.

Benefits

  • Wiring protected from overload
  • A rating that matches the circuit
  • Fewer nuisance trips
  • A labelled board that is easy to understand

Why choose us for MCB Installation

Our electricians are qualified, explain the work in plain language, give a price before they start and test everything before they leave. If something is unsafe we tell you, even when it is not part of the job.

Where we provide MCB Installation

Starting in Kathmandu Valley. Pick your area to see local details and book a visit.

MCB Installation: common questions

Why does my MCB keep tripping?
The usual causes are overload, a short circuit or a faulty appliance. A breaker that trips repeatedly is warning you of a problem, so it should not simply be replaced with a bigger one.
Can I fit a higher-rated MCB to stop the tripping?
Not safely. The breaker has to suit the cable behind it, and a higher rating can let the wiring overheat.
What is the difference between an MCB and a DB box?
The DB box is the enclosure that holds the breakers, and each MCB protects one circuit inside it.
Does every circuit need its own MCB?
Each circuit should have its own protection, and heavy appliances usually have a dedicated breaker.

Related services

Book this service

This is a request. Our team will confirm, reschedule or contact you. No payment is taken online.

Have an electrical question, or ready to book?

Ask us first, or request an appointment. In an emergency, just call.